Key takeaways
  • 12V models: 14.4 ± 0.2V CC/CV. 24V models: 28.8V per the model manual.
  • Recommended charge current is roughly capacity ÷ 5 hours: 20A for 100Ah, 63A for 314Ah.
  • Do not use lead-acid equalisation or desulphation modes.
  • Charge window from the manuals: 0–45°C on the 12V models, 0–50°C on the 24V models. No self-heating.

1. The charge profile

ModelCharge voltageRecommended currentMaximum continuous charge
12V 100Ah14.4 ± 0.2V20A100A
12V 314Ah14.4 ± 0.2V≈63ASee model manual
24V 100Ah28.8V20ASee model manual
24V 200Ah28.8V40ASee model manual

CC/CV means the charger holds the current limit until the pack reaches the target voltage, then holds the voltage while current tapers. A charger that keeps pushing 14.6–14.8V after full charge is not doing the pack a favour.

2. AC charger, DC-DC and solar

  • AC charger: use a LiFePO4 mode, set to the model’s charge voltage. Avoid “lithium” chargers that sit at 14.6–14.8V without a proper profile.
  • Alternator: use a LiFePO4-compatible DC-DC charger. A smart alternator’s voltage varies and a plain relay does not protect the pack.
  • Solar: use an MPPT controller with a lithium profile. Size the array for the daily load plus losses, and leave headroom for cold-weather Voc rise.
The BMS is a protection device, not a charge controller. It will disconnect on over-voltage or over-current, but it should not be the thing that limits normal charging.

3. How much current?

A practical rule is capacity ÷ 5 hours: 20A for 100Ah, about 63A for 314Ah, 40A for 24V 200Ah. Faster charging is possible within the model’s maximum, but heat and charger capability become the limit.

For a 314Ah pack, a 20A charger is fine but slow: from 20% to 100% is about 12.6 hours. The manual’s recommended charge current (0.2C) is 62.8A — around 5 hours; at 0.5C (157A) you reach about 97% in two hours. Plan the charge source around the turnaround time you actually need, not just the battery’s maximum.

4. Charging below 0°C

The manuals rate charging from 0°C: 0–45°C on the 12V models, 0–50°C on the 24V models. These models do not have self-heating. If the battery is below freezing, warm the space or the pack first; do not override the BMS.

5. Storage and wake-up

For storage the manual asks for 30–50% state of charge, in a dry place between −20 and 45°C, topped up at least once every 3–6 months, and a full charge before the battery goes back into service. If the battery will not wake, remove the load and recharge with a compatible charger; if it stays at 0V, contact support.

Common questions

Can I use a lead-acid charger?
Only if it has a LiFePO4/lithium mode and the correct voltage. Do not use equalisation, desulphation or temperature-compensation modes designed for lead-acid.
Can I charge directly from the alternator?
No. Use a LiFePO4-compatible DC-DC charger. The BMS protects the battery but does not regulate alternator current.

Models mentioned

12V 100Ah

1280 Wh

The everyday 12V pack. Light enough to swap by hand, with 100 A continuous output and room to expand to 20.48 kWh.

12V 314Ah

4019 Wh

Three times the capacity of the 100 Ah pack in one box — fewer parallel connections and a 200 A continuous / 600 A peak BMS.

24V 100Ah

2560 Wh

A native 25.6 V pack: half the current of a 12V pack at the same power. Series two for 48 V, parallel up to 2S4P.

24V 200Ah

5120 Wh

The largest capacity in the range: 5.1 kWh in one 24V case, 200 A continuous / 600 A peak, two in series for 48 V (2S2P).

Compare all models